My media is not circulating as good as what it was in the outer chamber of my Nexus.
You will need to check to see if your Airpump is working as it should be. The airline holes may have become blocked with limescale. To rectify this you will need to drain down the outer section and check the airline for any blockages.
How often do I need to change the media in my Nexus?
You should never need to change the media in your filter. You can add more to the outer chamber of your filter if required. Please see question 4 for more information before adding more.
How much water is drained to waste from my Nexus during a cleaning cycle?
In a Nexus 220+ 140 litres of water is drained to waste. In a Nexus 320+ just under 200 litres of water is drained to waste.
What is Nexus Automatic?
The Automatic is a separate system which can be fitted to Nexus filters, to enable automatic cleaning. By combining timers and automatic valves, Nexus can be converted and set to clean itself, as little or as often as required. It can be set to clean...
How can I extend the draining time of my Nexus Automatic?
You first need to remove the sticker of the far right side box and change the last dial with a small screwdriver from 50% to 40%, this will extend the cleaning time by one minute.
There is no power to the Nexus control box.
Check the wiring is correctly installed. Seek advice from a suitably qualified electrician if in doubt. Check the mains connection to the control box. Seek advice from a suitably qualified electrician if in doubt. Check the fuses inside the control...
How can I locate the fuse in the Nexus control box?
These are located alongside the timer blocks within their own hinged compartments. The fuses are all standard glass fuses; 10 Amp, 5 Amp, 2 Amp, 2 Amp from left to right.Please see the image below, this is where you can locate the fuses.
How do I set a Nexus Automatic to clean at a set time each day?
As its an analogue timer the cleaning frequency will be purely based on time so for example once every 24h, you can dictate the time by pressing manual clean at say 6pm and then it will automatically clean at 6pm the following day. On a twice a day clean...
Nexus Automatic does not close waste valve
To locate the issue you will need to:Check the relay furthest on the right in the auto box -Check the fuse - Does it light up during a cleaning cycle?If the relay is working as it should, you will need to check the motor. If it’s under warranty you will...
Can the Varipump be used with Nexus and EazyPod automatics?
Yes, the Varipump is ideal for using with either the Nexus or EazyPod automatic.
I have a nexus 320 pump fed automatic. I want to change to gravity fed. What do I need to purchase to do this.
Nexus Filters are supplied ready for pump fed installations. To convert it to gravity fed, please refer to the manual. https://evolutionaqua.com/pub/media/bss/productattachment/Nexus320_Manual-A5_Size-March-2021.pdfYou would also need to purchase spares...
What is the weight of a Nexus filter?
Nexus+ 220 (without water) weigh approximately 70kg on a pallet and Nexus+ 320 weigh approximately 90kg on a pallet.