FAQ Search Results

My Varipump has no flow?
Check the pump is wired correctly, the fuse has not blown and the pump his switched on at the controller. If using the pump dry, make sure it is primed Ensure any valves in the pipework are open If using a non-return valve verify the orientation...
Why is my Varipump noisy?
Verify airtight plumbing on the suction plumbing especially fittings! Clean out leaves or other debris from basket strainer (if applicable). Increase pipe size where possible. Decrease suction pipe length, reduce the number of elbows, etc Verify...
How long is the Varipump guarantee?
This product is guaranteed against defects in material and workmanship for two years from the date of purchase, under normal usage. The guarantee DOES NOT APPLY in case of improper use, negligence, lack of maintenance or accidental damage to the pump...
A fault code is displayed on the Varipump controller
The controller can display a fault code if the pump develops a problem. Download the fault code troubleshooting guide at the bottom of this page to identify the issue. If your Varipump was manufactured before 2021, the fault codes are: E01 = Pump is...
Are Varipumps self-priming?
No it is not self-priming. It will need to be placed below the water level.
What fittings do I need to connect the Varipump to pressure pipe?
To attach 2” pipework to the Varipump 20,000 and 30,000, you would need to use a 2” single union, threaded female to plain female, EA code: K82-76-66.You can then glue 2” pressure pipe directly into this. With the 10,000 you would need to use the...
Will water temperature effect the performance of eaBlanketweed?
If water temperature is below 8°, treatment efficiency is reduced. eaBlanketweed will be more effective as temperatures rise
My Varipump has a plug, can I cut the plug off?
You may find that your Varipump has a two pin plug - cutting the plug will not void your guarantee.The plug can be cut off and wired into a safe, compliant, outdoor electrical system, with an RCD cut-off. If you are unsure, consult a qualified electrician...
What fittings do I need to reduce the Varipump from 2" to 1.5" Pressure Pipe?
For a 20,000 and 30,000 Varipump you will need to connect a 2” single union, threaded female to plain female Ea code: K82-76-66. You will then need a Plain Reducing Bush-2" to 1.5" Ea Code: R81-063
Should I store my varipump in winter?
If there is a chance that the water will freeze over and restrict the flow, then you should take it out of the pond and dry it out. Store it over winter in a dry place, then reconnect the pump again in spring.
Where do I place the airpump?
If the pump is situated below the water level, it must have a non-return valve fitted to stop water siphoning back into the pump if there is a power cut.
Can the airpumps be used outside?
The airpumps are weather proof and can be used outside, they are not waterproof so do not situate in a position where they are likely to be flooded
I have replaced the diaphragm kit but my Airpump still does not work?
All the parts in the air pump can be replaced, if you have replaced the diaphragm kit and you pump still does not work it may be the electro-magnet. View electro-magnets
My airpump is running but no air is coming out?
The airpump is mounted to the base on rubber grommets, it is possible one of these has come out. Please refer to the manual and check the exploded diagram on page eleven, you will need a screwdriver and a pair of pliers to repair.
How do I clean the filter on my airpump?
To clean the filter on your airpump, follow the steps below or watch our YouTube video here: Step 1: Loosen the screw on top. Step 2: Remove the plastic filter cover. Step 3: Take the filter out and clean it with clean water and dry it. Step 4: ...
How do I change the activating arm on my airpump?
To change the activating arm on your airpump, follow the steps below or watch our YouTube video here: Step 1: Loosen the four screws around the cover and remove. Step 2: Loosen the four screws around the coil cover and remove. Step 3: Loosen the...
I have a nexus 320 pump fed automatic. I want to change to gravity fed. What do I need to purchase to do this.
Nexus Filters are supplied ready for pump fed installations. To convert it to gravity fed, please refer to the manual. https://evolutionaqua.com/pub/media/bss/productattachment/Nexus320_Manual-A5_Size-March-2021.pdfYou would also need to purchase spares...
What are the dimensions of Airpumps?
To identify the size of Airpumps, please click from one of the below options: Airpump 70 Dimensions Airpump 75 Dimensions Airpump 95 Dimensions Airpump 130 Dimensions Airpump 150 Dimensions
What are the Airpump Curves?
To identify the Airpump curves, please click from one of the below options: Airpump 70 Curves Airpump 75 Curves Airpump 95 Curves Airpump 130 Curves Airpump 150 Curves
My Airpump has a plug, can I cut the plug off?
You may find that your Airpump has a two pin plug - cutting the plug will not void your guarantee.The plug can be cut off and wired into a safe, compliant, outdoor electrical system, with an RCD cut-off. If you are unsure, consult a qualified electrician...
Did you find what you were looking for?